Intermec 3010 Installation Instruction

Page of 58
MaxiScan 3300 – Installation Guide – Edition 2.0
51
7 Troubleshooting
This section describes things you can try if you have problems with your MaxiScan
3300 during power-up, configuration and normal operation.
If you can not solve the problem yourself, please contact your Intermec representative.
Before you contact your Intermec representative
Go through the checklists below if you have any of the following problems:
no LEDs
no beeps
error beeps
no transmission
incorrect transmission
Setup problems—Checklist
system connected up correctly
system switched on
correct power-up beep indication—2 beeps
first and subsequent configuration bar codes are read before the end of the
default one minute configuration timeout. See 
Basic offline setup in Section 5—
Setup for more information
Reading problems—Checklist
correct symbologies selected for the bar codes you are trying to read
symbologies you read are available for your MaxiScan 3300
all unnecessary symbologies disabled
continuous configuration mode disabled (configuration inhibit after 1 minute
selected)
barcode length compatible with minimum / fixed length parameter settings of
MaxiScan 3300
MaxiScan 3300 configured for check digit and no check digit present in code