Intermec 1470 User Guide

Page of 316
1470/1471 Imager User’s Manual
4-20
Example
Decode only those bar codes with a count of 15 characters.
Minimum length = 15
Maximum length = 15
In the 2 of 5/93 tab of Visual Menu, enter the minimum message length in the Minimum
Length field and the maximum message length in the Maximum Length field under
Interleaved 2/5. Click the Write Settings to Device button (
) to send the new setting
to the imager.
Or scan one of the following bar codes.
Minimum Message Length
Maximum Message Length
The desired message length and Save must be input after reading this programming bar
code. Refer to the “General Programming Chart” in Appendix B.
Check Digit
When Check Digit is set to Validate but Don’t Transmit, the imager will only read
Interleaved 2 of 5 bar codes printed with a check digit but will not transmit the check
digit with the scanned data.