Intermec 1470 User Guide

Page of 316
Symbologies
4-29
4
Code 128 On/Off
In the CBAR/39/128 tab of Visual Menu, choose Decoding On under Code 128. Click
the Write Settings to Device button (
) to send the new setting to the imager.
Or scan one of the following bar codes. The default setting is marked with an asterisk
(*).
On
*
Off
Message Length
The message length selection is used to set the valid reading length of the bar code. If
the data length of the scanned bar code doesn’t match the valid reading length, the
imager will issue an error beep. You may wish to set the same value for minimum and
maximum length to force the imager to read fixed length bar code data. This
configuration helps reduce the chances of a misread.
Example
Decode only those bar codes with a count of 9-20 characters.
Minimum length = 09
Maximum length = 20
Example
Decode only those bar codes with a count of 15 characters.
Minimum length = 15