Intermec 1470 User Guide

Page of 316
1470/1471 Imager User’s Manual
5-30
Query Commands
Several special characters can be used to query the imager about its settings.
^
What is the default value for the setting(s)?
?
What is the imager’s current value for the setting(s)?
*
What is the range of possible values for the setting(s)? (The imager’s response uses
a dash (-) to indicate a continuous range of values. A pipe (|) separates items in a list
of non-continuous values.)
Examples of Query Commands
Example #1    What is the range of possible values for Codabar Coding Enable?
Enter:
cbrena*.
Response:
CBRENA0-1[ACK]
This response indicates that Codabar Coding Enable (CBRENA) has a
range of values from 0 to 1 (off and on).
Example #2    What is the default value for Codabar Coding Enable?
Enter:
cbrena^.
Response:
CBRENA1[ACK]
This response indicates that the default setting for Codabar Coding Enable
(CBRENA) is 1 or on.
Example #3    What is the imager’s current setting for Codabar Coding Enable?
Enter:
cbrena?.
Response:
CBRENA1[ACK]
This response indicates that the imager’s Codabar Coding Enable
(CBRENA) is set to 1 or on.
Example #4    What are the imager’s settings for all Codabar selections?
Enter:
cbr?.
Response:
CBRENA1[ACK],
CHK0[ACK],
CKX0[ACK],
SSX0[ACK],
MIN2[ACK],
MAX60[ACK],
DFT[ACK].