Intermec 1470 User Guide

Page of 316
1470/1471 Imager User’s Manual
4-8
Or scan one of the following bar codes.
Minimum Message Length
Maximum Message Length
The desired message length and Save must be input after reading this programming bar
code. Refer to the “General Programming Chart” in Appendix B.
Check Character
No Check Character indicates that the imager reads and transmits bar code data with or
without a check character.
When Check Character is set to Validate but Don’t Transmit, the imager will only read
Codabar bar codes printed with a check character but will not transmit the check
character with the scanned data.
When Check Character is set to Validate and Transmit, the imager will only read
Codabar bar codes printed with a check character and will transmit this character at the
end of the scanned data.
In the CBAR/39/128 tab of Visual Menu, choose a Check Character setting under
Codabar. Click the Write Settings to Device button (
) to send the new setting to the
imager.