Label Length Format
The next two sections explain how to set the Interleaved 2 of 5 
Label Length Format to either the Variable Length or Fixed 
Length Format.
Variable Length Format
You can set the Interleaved 2 of 5 symbology to Variable Length 
Format. 
To set the Interleaved 2 of 5 Variable Length Format
1
Identify the minimum length setting you want to make. You 
may choose any even number between 02 to 50
 
characters. 
2
Scan the SET bar code.
3
Scan the Enable Variable Length Format bar code.
4
Scan the Set Minimum Label Length bar code.
5
Using the Digits bar codes on page 93, scan the digits to set 
the minimum label length you identified in Step 1.
Don’t Transmit
 ---------
Transmit
 ---------
END----------------------------------- 
Note: For this symbology, the scanner decodes up to 50 
characters, but the actual length read varies depending upon 
the interface type, bar code physical size, and print quality.