Intermec SR60 Reference Guide

Page of 194
Chapter 3 — Configuring Label Transmit Settings
62
SR60 Scanner Programmer’s Reference Manual
Setting a Symbology-Specific Label ID
You can configure a label ID for each symbology.
To set a symbology-specific label ID
1
Using the ASCII table on page 164, identify the ASCII 
character(s) and the corresponding hex code(s) for the ASCII 
characters you plan to use as the label ID.
For example, suppose you want to change the label ID for 
UPC-A to A1. The ASCII chart shows that A equals 41 hex 
and 1 equals 31 hex. 
2
Scan the SET bar code on page 63.
3
Using the bar codes in “Selecting the Symbology” on page 63, 
scan the bar code representing the symbology whose Label ID 
you want to change.
For this example, you would scan the UPC-A symbology bar 
code.
4
Using the list of bar codes that starts on page 160, scan the 
four digits corresponding to the hex values you chose in 
 
Step 1. 
For this example, you would scan 4, 1, 3, and 1.
Position Label ID
 
as Suffix 
 ---------
END------------------------------------ 
Note: Successful programming requires four digits for the 
label ID.