Intermec SR60 Reference Guide

Page of 194
Chapter 4 — Enabling and Configuring Symbologies
84
SR60 Scanner Programmer’s Reference Manual
Configuring the Code 128/and UCC/EAN 128 Options
Scan the following bar codes to configure the Code 128 and 
UCC/EAN 128 options.
Minimum Label Length
You can set the Code 128 and UCC/EAN 128 Minimum Label 
Length.
To set the Code 128 and UCC/EAN 128 Minimum Label Length
1
Identify the minimum length setting you want to make. The 
selectable range is 00 to 80 characters.
2
Scan the SET bar code.
3
Scan the Set Minimum Label Length bar code.
4
Using the Digits bar codes on 
page 85, scan the digits to set
 
the minimum label length you identified in Step 1.
5
Scan the END bar code.  
Note: The scanner decodes up to 80 characters, but the actual 
length read varies depending upon interface type, the physical 
size of the bar codes, print quality, and whether the bar code 
data consists of Code 128 code set A, set B, or set C 
characters. (Because the C128 character set C allows for more 
densely packed data, if the bar code includes all or mostly 
C128 set C characters, more characters can be decoded).
Note: To set a label length less than ten, you must scan a zero 
digit first and then the length digit (such as 04, 06, or 08).
Minimum Label Length
SET------------------------------------ 
Set Minimum 
 
Label Length
 ---------