Intermec 4800 User Guide
3 - 7
Presentation Sensitivity
Presentation Sensitivity is a numeric range that increases or decreases the
imager's reaction time to bar code presentation. To set the sensitivity, scan the
Sensitivity bar code, then scan the degree of sensitivity (from 0-20) from the
inside back cover, and
imager's reaction time to bar code presentation. To set the sensitivity, scan the
Sensitivity bar code, then scan the degree of sensitivity (from 0-20) from the
inside back cover, and
Save. 0 is the most sensitive setting, and 20 is the least
sensitive.
Default = 1.
Hands Free Time-Out
The Scan Stand and Presentation Modes are referred to as “hands free” modes.
If the imager’s trigger is pulled when using a hands free mode, the imager
changes to manual trigger mode. You can set the time the imager should remain
in manual trigger mode by setting the Hands Free Time-Out. Once the time-out
value is reached, (if there have been no further trigger pulls) the imager reverts
to the original hands free mode.
If the imager’s trigger is pulled when using a hands free mode, the imager
changes to manual trigger mode. You can set the time the imager should remain
in manual trigger mode by setting the Hands Free Time-Out. Once the time-out
value is reached, (if there have been no further trigger pulls) the imager reverts
to the original hands free mode.
Scan the
Hands Free Time-Out bar code, then scan the time-out duration (from
0-300,000 milliseconds) from the inside back cover, and
Save. Default = 5,000
ms.
Reread Delay
This sets the time period before the imager can read the
same bar code a second
time. Setting a reread delay protects against accidental rereads of the same bar
code. Longer delays are effective in minimizing accidental rereads at POS (point
of sale). Use shorter delays in applications where repetitive bar code scanning
is required.
code. Longer delays are effective in minimizing accidental rereads at POS (point
of sale). Use shorter delays in applications where repetitive bar code scanning
is required.
Default = Medium.
Sensitivity
Hands Free Time-Out