Intermec 4800 User Guide

Page of 234
3 - 18
If you want a different notation than “NR,” for example, “Error,” or “Bad Code,” 
you can edit the output message using the 
code for the No Read symbol is 9C.  
Print Weight
Print Weight is used to adjust the way the imager reads Matrix symbols.  If a 
imager will be seeing consistently heavily printed matrix symbols, then a print 
weight of 6 may improve the reading performance.  For consistently light printing, 
a print weight of 2 may help.  After scanning the 
Set Print Weight bar code, set 
the print weight (from 1-7) by scanning digits from the inside back cover, then 
scanning 
Save.  Default = 4.
Video Reverse
Video Reverse is used to allow the imager to read bar codes that are inverted.  
The “Off” bar code below is an example of this type of bar code.  If additional 
menuing is required, Video Reverse must be disabled to read the menu bar 
codes and then re-enabled after menuing is completed.
Note: Images downloaded from the unit will not be reversed.  This is a setting for 
decoding only.
Set Print Weight
* Default
On
* Off