SATO CG412 User Guide

Page of 102
Section 7: Interface Specifications
CG4 Series Operator Manual
Page 7-3
7.2 RS232C SERIAL INTERFACE (cont’d)
Function descriptions
Function
Description
Baud rate setting
Select the data rate (bps) for the RS232 port.
Data bit length
Sets the printer to receive either 7 or 8 bits of data for each byte transmitted.
Parity setting
Selects the type of parity used for error detection.
Stop bit setting
Selects the number of stop bits to end each byte transmission.
Protocol setting
Selects the flow control and status reporting protocols
Synchro system
Asynchronous method
Maximum receive 
buffer capacity
1MB 
Code
ASCII (7 bits), Graphic (8 bits)
Transmission form
[Note] If using 7 bits, b8 will be omitted.
Signal level
High level
Low level
: +5 to +12V
: -5 to -12V
Interface type
Use Printer configuration tool or <DI> command.
<DI>a
Parameter
Item
Value
Description
a
Interface 
selection
0
USB
1
RS-232C
2
Keypad
3
Scanner/ Smart keyboard
Buffer near full 
Buffer near full 
0MB
1MB
Remaining 0.25MB
Remaining 0.5MB
occurred
released
Start 
b1 b2 b3 b4 b5 b6 b7 b8 
Stop