Aprilaire 800 User Guide

Page of 9
- 12 -
- 13 -
TEST/RESET
The Test/Reset feature allows the humidifier operation to be checked even 
if  there  is  no  call  for  humidity.  See  “Check  the  Humidifier  Operation”  on 
page 13 .
 
ADDITIONAL INFORMATION – AUTOMATIC MODE
Your  humidifier  is  a  precision  system  that  will  accurately  maintain  the 
humidity  in  your  home.  For  every  2°F  change  in  outdoor  temperature,  the 
Digital  Humidifier  Control  will  automatically  adjust  the  indoor  humidity  by 
1% .
The  Digital  Humidifier  Control  will  accurately  control  the  humidity  in  your 
home to a maximum of 45%. 
The humidity Values in 
Table 3 are targets based on outdoor temperature 
and the Digital Humidifier Control setting. The actual humidity may vary due 
to conditions in the home (cooking, showering, etc.).
TABLE 3 – % Relative Humidity Guide
 
Outdoor Temperature (°F)
 
 
-10°F 
0°F 
10°F  20°F  30°F  40°F
 
1 
10% 
10%  10% 
15% 
20%  25%
 
2 
10% 
10%  15% 
20% 
25%  30%
 
3 
10% 
15%  20% 
25% 
30%  35%
 
4 
15% 
20%  25% 
30% 
35%  40%
 
5 
20% 
25%  30% 
35%
 
40%  45%
 
6 
25% 
30%  35% 
40% 
45%  45%
 
7 
30% 
35%  40% 
45% 
45%  45%
Dial 
Setting
Relative 
Humidity 
(%)
Set  the  knob  to  “Test/Reset”,  make  sure  that  the  water  saddle  valve  is 
open and that the humidifier is on. The HVAC fan must be running for the 
humidifier to function. The humidifier will only operate for 1 minute in test 
mode.  Reduce  the  Humidifier  Control  setting  to  the  recommended  inside 
humidity, depending on the outside temperature. 
DO NOT LEAVE IN TEST 
MODE AS HUMIDIFIER wILL NOT OpERATE. 
CHECk THE HUMIDIFIER OpERATION
DIGITAL HUMIDIFIER CONTROL
TABLE 4 – Operation Guide
Condition
Solution
Condensation on windows.
Reduce the setting on the control dial by 
1 increment .
Lack of humidity.
Increase the setting on the control dial by 
1 increment .
Humidifier does not turn on .
Turn dial to “Test/Reset”. Make certain 
HVAC blower is operating. If unit still does 
not operate, consult a heating contractor.
Humidifier won’t shut off.
Turn control dial to “Off”. If unit continues 
to produce steam, turn off the humidifier 
and consult a heating contractor.
Test mode .
System operation is checked by setting 
the knob to “Test/Reset”. Make certain 
HVAC blower is operating. Humidifier will 
operate for one minute . 
Red “Call Dealer for Service” 
light flashes (
Figure 2).
Note the error code on the display (E1, 
E2, E3 or E4) and call your heating and air 
conditioning dealer .