Adaptec 7220ss User Guide

Page of 139
6-8
Managing Disk Drives and Enclosures
Managing SAF-TE Enclosures
An SEP is a SCSI device from which the RAID controller can 
inquire about environmental conditions such as temperature, 
power supply and fan status, and the presence or absence of disk 
drives. The RAID controller can also tell the SEP about RAID 
activities such as disk drive rebuilds and failed disk drives. 
SAF-TE configuration settings are automatically enabled when the 
controller is installed in a RAID appliance that contains a SEP. No 
changes are required to the default configuration settings to 
support SAF-TE. 
For SEP RAID appliances, you can:
Change the SEP LUN. See 
Change additional SEP settings. See 
.
Changing the SEP LUN
SEP LUNs allow access to SEPs. An SEP LUN may be set to a value 
between 0 and 63 or None. A setting of None means that the SEP 
cannot be accessed via a LUN. 
You may want to change the SEP LUN if it conflicts with the LUN 
of another device.
To change the SEP LUN:
1
From the System Menu, select Configuration Menu and press 
Enter
.
The Configuration menu appears.
2
Select SEP Configuration and press Enter.
The SEP Configuration menu appears.
3
Select SEP LUNs and press Enter.
The SEP LUNs prompt appears.
4
Select the LUN of the SEP you want and press Enter.
The SEP LUN prompt appears.