Blomberg taf 1230 User Manual

Page of 15
Operate the appliance only in well
ventilated, low dust rooms. Do not
block or cover the appliance's vent
slots.
The floor must have a sufficient load-
bearing capacity! If, for example, you
are stacking a washer and the dryer,
this combination can – when loaded –
reach a total weight of 160 kg.
Important:
• Place appliance on an even and level
floor only.
• Do not stand appliance on the power
cable.
• Keep at least 1 cm distance to walls or
other furniture.
Vent exhaust air out of doors!
The appliance has three exhaust outlets, at
the rear and the side panels; the side out-
lets are closed by removable covers.
The exhaust air should not be simply
led into the room, since the high hu-
midity may cause longterm damage
to walls and furniture.
• Connect the vent tube with the 90°
offset connector or the straight one
 to one of the exhaust air outlets.
• The two other outlets not used must
be closed by the covers.
The vent tube
– can be run through an open window
to the outside;
– can be connected to a wall-mount
vent.
The exhaust air must not be led into
flues or chimneys of fireplaces. Check
with your chimney sweeper or heating
engineer.
• Instead of the vent tube vent pipes
can be used. The diameter should be
at least 10 cm.
• Tube or pipe, respectively, should be
routed in the straightest and most di-
rect pathoutdoors, i.e. with the fewest
number of elbows and turns, as these
hamper airflow.
• The maximum length of a straight
routed tube/pipe is given in the chart
below.
• For each elbow and other obstructions
the respective value shown is to be de-
ducted from the maximum length.
Built-under installation
This appliance can be installed under a
worktop.
• For this a special top cover is required
(stock no. AP 2000), available at the
customer service or specialised trade.
Hose 
Pipe
Max. length
8.0 m
10.0 m
less…
1 elbow 45°
– 1.0 m
– 0.3 m
1 elbow 90°
– 1.8 m
– 0.6 m
1 elbow 90° short turn
– 2.7 m
1 wall-mount vent* 
–  2.0 m
– 2.0 m
* with automatic louvers
4