Panasonic hd-ag-3dp1 User Manual

Page of 140
4
Chapter
4
Adjustments
and
Settings
for
Recording
Center Marker Display
A center marker is displayed when the menu option 
MARKER in the DISPLAY SETUP screen is set to ON.
 NOTE
The center marker display appears only on the LCD monitor 
and in the viewfinder. It is not superimposed on signals output 
via the HD SDI MONITOR OUT and HDMI connectors.
Safety Zone Markers
A safety zone marker is displayed when the menu option 
SAFETY ZONE is selected in the DISPLAY SETUP screen.
• OFF: Not displayed
• 90%:  indicates the display area on a normal household 
TV
• 13:9:  Indicates the display area available at a 13:9 aspect 
ratio.
• 14:9:  Indicates the display area available at a 14:9 aspect 
ratio.
 NOTE
Safety zone markers appear only on the LCD monitor and in 
the viewfinder. They are not superimposed on signals output 
via the HD SDI MONITOR OUT and HDMI connectors.
Zebra Pattern Display
The AG-3DP1 can display two zebra patterns.
The zebra pattern set in the menu appears on the LCD 
monitor and in the viewfinder when the ZEBRA button is 
pressed or if the ZEBRA switch on the viewfinder is set to 
ON.
ZEBRAbutton
Use the DISPLAY SETUP screen to set the level of zebra 
pattern display.
Item
Setting
Description
ZEBRA1 
DETECT
50%…70%…109%
Sets the level of the 
right-leaning zebra 
pattern 1.
ZEBRA2 
DETECT
50%…85%…109%
Sets the level of the 
left-leaning zebra 
pattern 2.
ZEBRA2
ON, SPOT, OFF
Selects the ZEBRA2 
type.
Underlined values indicate factory defaults.
SPOT:  A video level between ZEBRA1 and ZEBRA2 
displays a zebra pattern.
SPOT
OFF
ON
109%
0%
ZEBRA 2
DETECT
ZEBRA 2
ZEBRA 1
DETECT
Imagelevel
 NOTE
The zebra pattern cannot be displayed when the 3D assist 
function is operating.