 Lamp replacement procedure
1
 Turn power off, wait until power 
indicator stops blinking red, then 
unplug the power cord from the 
wall outlet and confirm that the area 
around the lamp unit has cooled 
down.
POWER
button /
POWER
indicator
Lamp Re placement
3
 Loosen the Lamp cover screw.
First read caution and warn ing
labels on lamp cover. Then, loosen 
the lamp cover screw by using a 
screwdriver.
Lamp unit screw
Screwdriver
4
Loosen the lamp unit screw with a 
screwdriver. Then, grasp the lamp 
unit as shown in the diagram, and 
slowly remove from the projection 
display.
2
 Remove the Front cover. Place your 
fingertips under the Front cover and 
pull it from the projection display.
Lamp unit handle
Lamp cover handle
6
 Replace the Lamp unit and cover 
screws. Tighten the lamp unit/cover 
screw with a screwdriver.
• Properly dispose of old lamp. Please see the
operating instructions for the projection display.
Note
7
 Replace the Front cover.
5
Insert the new lamp unit being careful 
of the insertion direction.
• Press on the arrow mark making sure 
insertion is done correctly.
 Lamp time reset procedure
1
Be sure the power cord is plugged 
into a properly grounded wall outlet. 
Then, press the POWER button on the 
projection display or the remote control 
to turn the unit on.
Warning:
Perform lamp time reset only when the lamp has 
been replaced.
When lamp time reset is finished, the LAMP 
indicator goes out.
Note
After lamp re placement,
follow the pro cedure below
3
When reset 
procedure
is complete, 
the screen on 
the right will 
appear.
and
Lamp cover screw
LAMP indicator
2
While pressing the VOL- button on 
the projection display, hold down the 
PIP or SPLIT button on the remote 
control at same time for more than 
5 seconds.
LSQC0334 C
      LAMP TIME WAS
       RESET TO 0.
                END
Front cover
This product has a High Intensity Discharge (HID) 
lamp that contains a small amount of mercury.
Disposal of these materials may be regulated 
in your community due to environmental 
considerations.
For disposal or recycling information please contact 
your local authorities, or the Electronics Industries 
Alliance: <http://www.eiae.org.>
CAUTION:
Because of the possibility of injury, strictly follow 
the replacement procedure below.
• Please wait more than one hour for lamp 
replacement.
  [If you need to replace the lamp more urgently]
• The Projection display has a forced cooling 
feature. After the POWER button is turned OFF, 
and during the first minute of the normal cooling 
fan operation, press the VOL+ button on the 
projection display and   button on the remote 
control at same time for more than 5 seconds. The 
cooling fan operates for about 10 minutes. The 
LAMP indicator flashes red 5 times every 5 
seconds.
Attach the lamp unit and lamp unit housing door 
securely. If the lamp unit and lamp unit housing 
door are not attached securely, the protective 
circuit will be activated and the lamp will not turn 
on.
* This screen may be 
different from the actual 
screen.
For models PT-50LC13/
PT-60LC13/PT-50LCX63/
PT-60LCX63/PT-43LCX64/
PT-50LCX64/PT-60LCX64
For models PT-43LC14/
PT-50LC14/PT-60LC14
CAUTION
• Because the lamp unit is hot immediately after
its use, touching it may cause burns.
Please allow the lamp to cool before handling or
replacing the lamp unit.