CONNECT THE FMA-101 TO THE HOTEL’S DISTRIBUTION NETWORK 
 
Complete the following steps to connect the FMA-101 to the hotel’s coaxial distribution 
network and Internet connection. 
 
1.
  Mount a 6ELP-50 or 6MLP-50 low pass filter to the FTG rack. 
2.
  Connect a coaxial cable from the RF OUT connector on the FMA-101 to the low pass filter. 
3.
  Terminate the RF IN port on the FMA-101. 
4.
  Connect a coaxial cable from the low pass filter to an input port on the FTG rack combiner. 
5.
  Connect an Ethernet straight-through cable from the FMA-101 Ethernet port to the hotel’s 
Internet connection or network, if available. 
6.
  Use a Sencore SLM-1456 meter to balance the FMA-101 forward signal with the FTG 
channels installed in the FTG Basic platform. Note: The FMA-101 outputs a forward signal 
at 50.5 MHz, the same forward signal frequency as a KSR. 
7.
  Verify the forward signal is between 3 dB and 10 dB in the guest rooms.