Panasonic th-50pf9 User Manual

Page of 48
11
Connections
SERIAL Terminals connection
Notes:
•  Use the RS-232C cable to connect the computer to the Plasma Display.
•  The computer shown is for example purposes only.
•  Additional equipment and cables shown are not supplied with this set.
The SERIAL terminal conforms to the RS-232C interface specifi cation, so that the Plasma Display can be controlled by a 
computer which is connected to this terminal.
The computer will require software which allows the sending and receiving of control data which satisfi es the conditions 
given below. Use a computer application such as programming language software. Refer to the documentation for the 
computer application for details.
The SERIAL terminal is used when the Plasma Display is controlled by a computer.
Communication parameters
Basic format for control data
The transmission of control data from the computer 
starts with a STX signal, followed by the command, 
the parameters, and lastly an ETX signal in that order. 
If there are no parameters, then the parameter signal 
does not need to be sent.
Notes:
•  If multiple commands are transmitted, be sure to wait 
for the response for the fi rst command to come from 
this unit before sending the next command.
•  If an incorrect command is sent by mistake, this unit will 
send an “ER401” command back to the computer.
With the power off, this display responds to PON command only.
6
7
8
9
1
3
4
5
2
SERIAL
Pin layout for SERIAL Terminal 
COMPUTER
RS-232C Straight cable
D-sub 9p
Start
(02h)
3-character
command (3 bytes)
Colon
Parameter(s)
(1 - 5 bytes)
End
(03h)
STX
C1 C2 C3
P1 P2 P3 P4
:
P5
ETX
Command
Command
PON
POF
AVL
AMT
IMS
DAM
Control details
Power ON
Power OFF
Volume 00 - 63
Audio MUTE OFF
Audio MUTE ON
Input select (toggle)
Slot1 input
Slot2 input
Slot3 input
PC input
Screen mode select (toggle)
NORMAL (4 : 3)
ZOOM
FULL
JUST
Panasonic AUTO
Parameter
None
None
**
0
1
None
SL1
SL2
SL3
PC1
None
NORM
ZOOM
FULL
JUST
SELF
Signal level
Synchronization method
Baud rate
Parity
Character length
Stop bit
Flow control
RS-232C compliant
Asynchronous
9600 bps
None
8 bits
1 bit
-
2
3
4
5
6
7
8
9
1
RS-232C Conversion cable
 D-sub 
9-pin 
female 
Details
 
 
R X D
  
D
  
GND
  
• 
Non use 
 
 
 
 
Shorted 
 • 
NC