Panasonic DBS 576 Technical Manual
![Panasonic](https://files.manualsbrain.com/attachments/8f677e63fb64cbb6c62d09e6242996e7631380a8/common/fit/150/50/34d700d3fb727c767799b2da5cc474b219c0a4312e9e3044c99491a2fb9a/brand_logo.png)
6-52
DBS 576 (USA) issued September 2001
576-50-700
Chapter 6. DSLT Features
Section 700 - Operation
Hardware Requirements
•
N/A
Related Programming
•
FF1: MCO Access
•
FF1-2: Dial Plan
•
FF5-2: MCO Trunk Group (Outbound)
•
FF7: ARS/TRS
Considerations
•
The System supports up to 576 outside lines in a six-cabinet configuration. These lines can be
divided into 99 different trunk groups.
•
Each trunk group can support up to 50 outside lines.
•
Each MCO Tenant Group can have up to 5 MCO trunk access codes. System defaults for MCO
trunk access codes are displayed in the following table.
•
MCO1 can have up to 5 trunk groups assigned by the Advanced Trunk Group feature.
•
MCO1 access code is used for Automatic Route Selection (ARS) access code.
Table 2.
MCO Trunk Access Codes
Trunk Queuing
Description
When you try to originate a call by MCO (enter 9) and all outside lines in a trunk group are busy, the
System can call you when a line becomes free. Simply pick up the handset and dial the telephone
number when the Trunk Callback alert tone rings.
2. Enter the desired trunk access number (9 or 81-84). (See
Outside dial tone
3. Dial the phone number.
MCO Group
Trunk Access Code
MCO1
9
MCO2
81
MCO3
82
MCO4
83
MCO5
84
Action
Result