Panasonic DBS 576 Technical Manual
![Panasonic](https://files.manualsbrain.com/attachments/8f677e63fb64cbb6c62d09e6242996e7631380a8/common/fit/150/50/34d700d3fb727c767799b2da5cc474b219c0a4312e9e3044c99491a2fb9a/brand_logo.png)
3-16
DBS 576 (USA) issued September 2001
576-50-700
Chapter 3. System Features
Section 700 - Operation
Related Programming
•
FF2: Trunk COS
•
FF3: Extension COS Assignments
Considerations
•
N/A
Class of Service - T1 Trunk Ring Back Service Tone
With Version 3.5 and higher, the system can be programmed to send a simulated ring back tone to T1
trunks when the CO does not provide a ring back tone.
Hardware Requirements
•
N/A
Related Programming
•
FF1-0-04: Trunk COS
Considerations
•
Supports Ground Start/Loop Start Trunks
Class of Service - Trunk to Trunk Restriction
Trunk to Trunk COS allows or restricts call transfers from one trunk to another trunk based on the
originating and receiving trunk COS.
Hardware Requirements
•
N/A
Related Programming
•
FF1-0-04: Class of Service Trunk/Tie
•
FF1-0-11: Trunk-Trunk Restriction
Considerations
•
N/A
Class of Service - Extension (Station) Timers
Prior to CPC Version 2.0, timers related to certain extension functions such as the Hold Recall Timer
were only available on a system-wide basis. Beginning with CPC Version 2.0 these extension
functions may continue to use the same system-wide timers or a newly added Station Timer Class
settings. Up to eight Station Timer Classes may be specified. Then an extension may be assigned a
Station Timer Class.
The following table shows the extension timers that may be assigned on a class basis.