Hisense kf-34gwe User Guide

Page of 28
   
Appendix: Installation
     This operation manual has explicit information for 
installation and maintenance in most conditions. Contact 
the local distributor or after-sales service for further 
information.
A.  Wiring 
   Only qualified professionals should carry out wiring 
of the appliance.
    Disconnect  the  power  supply  before  completion  of 
wiring, piping or checking the appliance.
    Voltages generated by the appliance is fatal.
Read the electrical schematic diagram and explanation 
before installation. Improper installation and earth 
connection may result in fatal injury.
      Connect  the  earth  as  required  by  local  wiring 
regulations.
  Tightly fasten all the wiring connections to prevent 
overheating or fire.
    Special  power  source,  switches  and  sockets  are 
required for the power supply of the appliance.
    Electric  meter  capacity  must  be  larger  than  or 
equivalent to 16A.
B. Transport
    Carefully move the outdoor unit.
C. Installation
----When the appliance is mounted to the ceiling or the 
wall,
     Make sure that the ceiling or the wall is strong 
enough for the appliance.
Read the operation manual before installation and keep 
this manual in a safe place.
1-1 Tools
1. Screwdriver
2. Phillips head screwdriver
3. Knife or wire stripper
4. Steel ruler
5. Spirit level
6. Hammer
7. Percussion drill
8. Tube cutter
9. 
 flarer
10. 
 bender
11. Adjustable spanner
1-2  Attachment
     (see the packing list)
1-3  Parts Package
Copper tubes, components and insulation materials for 
the outdoor unit.
1-4 Type of the copper tube and insulation materials
Tube
Tube
   
1. Summary
   Make a wood or metal frame to support the appliance if 
     necessary.
----When the appliance is mounted in a room,
     Properly insulate the tube of indoor unit, and make 
sure there is no water drops   on the appliance or on 
the floor.
----When the appliance is installed on a damp or uneven 
area,
   Make a flat concrete base and place the base under the 
outdoor unit.
----When the appliance is installed in an area of strong 
winds.
      Using  anchor  bolts  and  metal  frames  to  fix  the 
properly covered outdoor unit.
----When the appliance (Model Heat Pump) is installed in 
an area of heavy snow.
   The outdoor unit must be installed in a position above 
the snow accumulation.
D. Connection
    Use the shortest tubes possible
    Using a flaring method
    Smear  some  refrigeration  oil  between  the  flared 
surface and the connected tube.
      Fasten  the  nuts  with  a  torque  wrench  to  prevent 
leakage of refrigerant.
    Check for leakage before trial operation.
E. Maintenance
  Disconnect the power before checking the electrical 
components and the circuits.
    Avoid contact with the moving parts of the appliance.
    Clear the site and make sure there is no installation 
debris left in the appliance.
F. Other
    Keep the room well ventilated during installation.
1. Table 1 indicates that tubes should be cut with an 
additional length of 30cm-40cm, to reduce the vibration 
from the outdoor unit.
2. The insulation materials for the copper tubes should 
conform to the required length and the wall thickness 
should not be less than 8mm.
3. Insulated copper wires should be used for wiring and 
the specification should depend on the length.
1-5  Additional materials for installation
1. white tape
2. nails or clips (as required)
3. putty
4. refrigeration oil
5. clips for fixing refrigerant tubes
Warning: Carrying out operations displaying this
               symbol may result in fatal injury.
Caution: Carrying out operations displaying this
              symbol may result in serious injury.
 
 
                                                  Narrow  tube
                                                 
Wide tube
       Outside Diameter       Thickness      Outside Diameter   
20