Hisense kf-34gwe User Guide
Appendix: Installation
This operation manual has explicit information for
installation and maintenance in most conditions. Contact
the local distributor or after-sales service for further
information.
A. Wiring
Only qualified professionals should carry out wiring
of the appliance.
Disconnect the power supply before completion of
wiring, piping or checking the appliance.
Voltages generated by the appliance is fatal.
Read the electrical schematic diagram and explanation
before installation. Improper installation and earth
connection may result in fatal injury.
Connect the earth as required by local wiring
regulations.
Tightly fasten all the wiring connections to prevent
overheating or fire.
Special power source, switches and sockets are
required for the power supply of the appliance.
Electric meter capacity must be larger than or
equivalent to 16A.
B. Transport
Carefully move the outdoor unit.
C. Installation
----When the appliance is mounted to the ceiling or the
wall,
Make sure that the ceiling or the wall is strong
enough for the appliance.
Read the operation manual before installation and keep
this manual in a safe place.
1-1 Tools
1. Screwdriver
2. Phillips head screwdriver
3. Knife or wire stripper
4. Steel ruler
5. Spirit level
6. Hammer
7. Percussion drill
8. Tube cutter
9.
flarer
10.
bender
11. Adjustable spanner
1-2 Attachment
(see the packing list)
1-3 Parts Package
Copper tubes, components and insulation materials for
the outdoor unit.
1-4 Type of the copper tube and insulation materials
Tube
Tube
1. Summary
Make a wood or metal frame to support the appliance if
necessary.
----When the appliance is mounted in a room,
Properly insulate the tube of indoor unit, and make
sure there is no water drops on the appliance or on
the floor.
----When the appliance is installed on a damp or uneven
area,
Make a flat concrete base and place the base under the
outdoor unit.
----When the appliance is installed in an area of strong
winds.
Using anchor bolts and metal frames to fix the
properly covered outdoor unit.
----When the appliance (Model Heat Pump) is installed in
an area of heavy snow.
The outdoor unit must be installed in a position above
the snow accumulation.
D. Connection
Use the shortest tubes possible
Using a flaring method
Smear some refrigeration oil between the flared
surface and the connected tube.
Fasten the nuts with a torque wrench to prevent
leakage of refrigerant.
Check for leakage before trial operation.
E. Maintenance
Disconnect the power before checking the electrical
components and the circuits.
Avoid contact with the moving parts of the appliance.
Clear the site and make sure there is no installation
debris left in the appliance.
F. Other
Keep the room well ventilated during installation.
1. Table 1 indicates that tubes should be cut with an
additional length of 30cm-40cm, to reduce the vibration
from the outdoor unit.
2. The insulation materials for the copper tubes should
conform to the required length and the wall thickness
should not be less than 8mm.
3. Insulated copper wires should be used for wiring and
the specification should depend on the length.
1-5 Additional materials for installation
1. white tape
2. nails or clips (as required)
3. putty
4. refrigeration oil
5. clips for fixing refrigerant tubes
Warning: Carrying out operations displaying this
symbol may result in fatal injury.
Caution: Carrying out operations displaying this
symbol may result in serious injury.
symbol may result in fatal injury.
Caution: Carrying out operations displaying this
symbol may result in serious injury.
Narrow tube
Wide tube
Outside Diameter Thickness Outside Diameter
20