10
C
HAPTER
 1: P
RODUCT
 O
VERVIEW
Redundant power 
system LED 
RPS 
Solid green
The AC power supply is normal and 
the RPS is connected and works 
normally. 
Solid yellow
The RPS input is normal, but an AC 
input failure occurs or no AC power 
is connected. 
OFF
No RPS is connected. 
Module LED 
MOD  Solid green
The module is in position and works 
normally. 
Flashing yellow
The switch does not support the 
module or a module failure occurs. 
OFF
No module is installed. 
7-segment digital LED  Unit 
POST running
The power LED flashes green  The LED displays the POST test ID. 
  
POST failed
The power LED flashes red 
The LED flashes the POST test ID of 
the failed test. 
  
Software loading
The power LED flashes green. A bar rotates clockwise around the 
LED. 
  
Fan failure
The power LED is solid red. 
The LED displays F
  
Over-temperature alarm
The power LED is solid red. 
The LED displays t
  
Cluster state
The power LED is solid green.  For a command switch, the LED 
displays C.
For a member switch, the LED 
displays S.
For a candidate switch, the LED 
displays c.
The LED displays 1 if there is only one 
unit. 
Table 4   LEDs on the front panel of the Switch 4800G 24-Port
LED Mark 
Status 
Description