Installing a Fan Tray
41
Figure 17   Rear View of a Switch 4005 Fan Tray
Verify that the fan tray is flush with the back of the chassis; do not leave the fan 
tray partially out of the slot. If the fan tray and the chassis are not properly aligned, 
remove the fan tray and reseat it. Do not tighten the screws to seat the fan tray.
Secure the fan tray to the chassis by tightening the two external retaining screws 
with a flathead screwdriver. 
Tighten the screws to a Torque Specification of 1.5 kg-cm (1.3 in-lb).
NOTE: 
The fans begin rotating when you power on the chassis or when the 
connector on a newly inserted fan tray makes contact with the backplane 
connector in a powered-on chassis.
Visually inspect all installed fans to verify that each is turning continuously when 
the chassis is powered up. 
If one of the fans in a fan tray is not running at all or is running intermittently, 
remove and reinsert the fan tray. If problems continue, replace the fan tray with a 
different one.