If the system information is output before you input any information following the current command 
line prompt, the system does not echo any command line prompt after the system information 
output. 
In the interaction mode, you are prompted for some information input. If the input is interrupted by 
system output, no system prompt (except the Y/N string) will be echoed after the output, but your 
input will be displayed in a new line. 
 
Configuring to Display the Time Stamp with the UTC Time Zone 
To add UTC time zone to the time stamp in the information center output information, you must: 
Set the local time zone 
Set the time stamp format in the output destination of the information center to date 
Configure to add the UTC time zone to the output information 
Follow these steps to configure to display time stamp with the UTC time zone: 
To do… 
Use the command… 
Remarks 
Set the time zone for the system 
clock timezone zone-name 
add | minus } time 
Required 
By default, UTC time zone is set 
for the system. 
Enter system view 
system-view 
— 
Log host 
direction 
info-center timestamp 
loghost date
 
Set the time stamp 
format in the output 
destination of the 
information center 
to date 
Non log 
host 
direction 
info-center timestamp { log 
| trap 
| debugging date 
Required 
Use either command 
Set to display the UTC time zone 
in the output information of the 
information center 
info-center timestamp utc 
Required 
By default, no UTC time zone is 
displayed in the output 
information 
 
Setting to Output System Information to the Console 
Setting to output system information to the console 
Follow these steps to set to output system information to the console: 
To do… 
Use the command… 
Remarks 
Enter system view 
system-view 
— 
Enable the 
information center 
info-center enable 
Optional 
Enabled by default.