3com 5500-ei pwr Installation Instruction
1-5
Note that:
z
The remote-ping server function is needed only for jitter, TCP, and UDP tests.
z
You can configure multiple TCP/UDP listening services on one remote-ping server, with each
listening service corresponding to a specific destination IP address and port number.
remote-ping Client Configuration
remote-ping client configuration
After remote-ping client is enabled, you can create multiple test groups for different tests, without the
need to enable remote-ping client repeatedly for each test group.
Different types of remote-ping tests are somewhat different in parameters and parameter ranges. The
following text describes the configuration on remote-ping client for different test types.
Among the test types supported by remote-ping, only the ICMP test can be performed when XRN fabric
is enabled; all other test types cannot be performed when XRN fabric is enabled. With XRN fabric
enabled, you are allowed to configure remote-ping tests and use the display commands to check your
configurations, but for non ICMP tests, the remote-ping tests you configured cannot be executed until
fabric is disabled.
1) Configuring ICMP test on remote-ping client
Follow these steps to configure ICMP test on remote-ping client:
To do…
Use the command…
Remarks
Enter system view
system-view
—
Enable the remote-ping client
function
function
remote-ping-agent enable
Required
By default, the remote-ping
client function is disabled.
client function is disabled.
Create a remote-ping test
group and enter its view
group and enter its view
remote-ping
administrator-name
operation-tag
administrator-name
operation-tag
Required
By default, no test group is
configured.
configured.
Configure the destination IP
address
address
destination-ip ip-address
Required
By default, no destination
address is configured.
address is configured.
Configure the source IP
address
address
source-ip ip-address
Optional
By default, no source IP
address is configured.
address is configured.
Configure the test type
test-type icmp
Optional
By default, the test type is
ICMP.
ICMP.