3com 5500-ei pwr Reference Guide

Page of 1314
 
1-3 
clock timezone 
Syntax 
clock timezone zone-name { add | minus } HH:MM:SS 
undo clock timezone 
View 
User view 
Parameters 
zone-name: Name of the time zone, in length of 1 to 32 characters. 
add: Specifies to add a time value based on the universal time coordinated (UTC) time to generate a 
later time. 
minus: Specifies to subtract a time value based on the UTC time to generate an earlier time. 
HH:MM:SS: Time to be added or subtracted from the UTC time, in the form of HH:MM:SS. 
Description 
Use the clock timezone command to set the local time zone. 
Use the undo clock timezone command to restore the local time zone to the default UTC time zone. 
After the setting, you can use the display clock command to check the setting. The log information time 
and the debugging information time adopts the local time after the time zone and the summer time have 
been adjusted. 
Related commands: clock summer-timedisplay clock
Examples 
# Set the local time zone named z5, which is five hours ahead of the UTC time. 
<Sysname> clock timezone z5 add 05:00:00 
<Sysname> display clock 
05:03:17 z5 Mon 01/01/2001 
Time Zone : z5 add 05:00:00 
Summer-Time : abc1 one-off 06:00:00 08/01/2005 06:00:00 09/01/2005  01:00:00 
quit 
Syntax 
quit 
View 
Any view 
Parameters 
None 
Description 