Field 
Description 
Sampling interval 
Sampling interval, in seconds. The system 
performs absolute or delta sampling on the 
sampled node at this interval. 
Rising threshold 
Rising threshold. When the sampled value 
equals or exceeds the rising threshold, an alarm 
is triggered. 
Falling threshold 
Falling threshold. When the sampled value 
equals or falls under the falling threshold, an 
alarm is triggered. 
When startup enables 
The condition under which an alarm is triggered, 
which can be: 
risingOrFallingAlarm: An alarm is triggered 
when the rising or falling threshold is 
reached. 
risingAlarm: An alarm is triggered when the 
rising threshold is reached. 
FallingAlarm: An alarm is triggered when the 
falling threshold is reached. 
Latest value 
The value of the latest sample 
 
display rmon event 
Syntax 
display rmon event [ event-entry 
View 
Any view 
Parameters 
event-entry: RMON event entry index, in the range 1 to 65535. If you do not specify the event-entry 
argument, the configuration of all the RMON event entries is displayed. 
Description 
Use the display rmon event command to display the configuration of a specified RMON event entry. 
RMON event information includes the following: 
Event entry index 
Event entry owner 
Event description 
The action triggered by the event (log or alarm messages) 
The time (in seconds) when the latest event is triggered (in terms of the time elapsed since the 
system is started/initialized). 
Related commands: rmon event
Examples 
# Display the configuration of all the RMON event entries. 
<Sysname> display rmon event