2-6
View
Any view
Parameters
prialarm-entry-number: Extended alarm entry Index, in the range 1 to 65,535.
Description
Use the display rmon prialarm command to display the configuration of an RMON extended alarm
entry. If you do not specify the prialarm-entry-number argument, the configuration of all the extended
alarm entries is displayed.
The information in an extended alarm entry includes: sampling type, variable formula of the sampled
node, sampling interval, rising and falling thresholds that trigger an alarm, the condition under which an
alarm is triggered, and the last sampled value.
Related commands: rmon prialarm.
Examples
# Display the configuration of all the extended RMON alarm entries.
<Sysname> display rmon prialarm
Prialarm table 1 owned by user1 is VALID.
Samples type : absolute
Variable formula : ((.1.3.6.1.2.1.16.1.1.1.4.1)*100)
Description :
Sampling interval : 10(sec)
Rising threshold : 10000(linked with event 1)
Falling threshold : 2000(linked with event 1)
When startup enables : risingOrFallingAlarm
This entry will exist : forever.
Latest value : 0
Table 2-5 display rmon prialarm command output description
Field
Description
Prialarm table
Index of an entry in the extended alarm table
owned by user1
Entry owner: user 1
VALID
The alarm entry identified by the index is valid.
Samples type
Sampling type: absolute or delta
Variable formula
Variable formula of the sampled node
Description Description
Sampling interval
Sampling interval in seconds. The system
collects statistics of the port at this interval.
collects statistics of the port at this interval.
Rising threshold
Rising threshold. When the sampled value
equals or exceeds the rising threshold, an alarm
is triggered.
equals or exceeds the rising threshold, an alarm
is triggered.
Falling threshold
Falling threshold. When the sampled value
equals or falls under the falling threshold, an
alarm is triggered.
equals or falls under the falling threshold, an
alarm is triggered.