3com 8807 Reference Guide

Page of 1099
System Status and System Information Query Commands
1029
The maximum time value supported by this command is 23:59:59 9999/12/31.
Related command: clock datetime.
Example
# View the current system date and time.
<SW8800> display clock
 
18:36:31 beijing Sat 2002/02/02
 
Time Zone : beijing add 01:00:00
 
Summer-Time : bj one-off 01:00:00 2003/01/01 01:00:00 2003/08/08 01:00:00 
display debugging
Syntax
display debugging [ interface interface-type interface-number ] [ module-name 
]
View
Any view
Parameter
interface-type: Interface type supported by the switch, including Ethernet, 
GigabitEthernet, AUX, and Vlan-interface.
interface-number: Interface number.
module-name: Module name.
Description
Use the display debugging command to display debugging that has been 
enabled.
You can execute the display debugging to view the specific debugging that has 
been enabled. If the command is executed without any parameter specified, the 
system will display all debugging that has been enabled.
Related command: debugging.
Example
# Display all debugging that has been enabled.
<SW8800> display debugging
 
Multicast packet forwarding debugging switch is on 
display fiber-module
Syntax
display fiber-module [ interface-type interface-number ]
Table 150   Description on the fields of the display clock command
Field 
Description 
18:36:31 beijing Sat 2002/02/02 
Current system time 
Time Zone : beijing add 01:00:00 
Configured time zone information 
Summer-Time : bj one-off 01:00:00 
2003/01/01 01:00:00 2003/08/08 01:00:00 
Configured summer time information