3com 8807 Reference Guide

Page of 1099
Ethernet Port Configuration Commands
137
Parameter
interval: Interval of performing statistics on ports in seconds. It is 300 seconds by 
default.
Description
Use the flow interval command to set the interval of performing statistics on 
ports. The switch performs the statistics about the average speed during the 
interval.
Use the undo flow-interval to restore the interval to the default value.
Related command: display interface.
Example
# Set the interval of performing statistics on Ethernet3/1/1 to 100 seconds.
<SW8800>system-view
 
System View: return to User View with Ctrl+Z.
 
[SW8800]interface Ethernet 3/1/1
 
[3Com-Ethernet3/1/1] flow-interval 100 
# Restore the interval o f performing statistics on Ethernet 3/1/1 to the default 
value.
[3Com-Ethernet3/1/1] undo flow-interval 
link-status hold
Syntax
link-status hold hold-time
undo link-status hold
View
System view
Parameter
hold-time: Sets time interval (in seconds) for port suppression. The value 0 
indicates that port suppression is not enabled. By default, the time interval is 3 
seconds.
Description
Use the link-status hold hold-time command to set port hold time. If the 
Down/Up operation is implemented on ports too frequently, the switch may fail. 
Therefore, the function is provided to prohibit frequent change of the port status.
Use the undo link-status hold command to restore the default port hold time, 3 
seconds.
Related command: display interface.
Example
# Set the port hold time to 5 seconds.