PoE PSU Supervision Display Commands
891
display poe-power 
dc-output value
Syntax
display poe-power dc-output value
View
Any view
Parameter
None
Description
Use the display poe-power dc-output value command to display the DC 
output voltage/current value of the PoE PSUs.
Example
# Display the DC output voltage/current value of the PoE PSUs.
<SW8800> display poe-power dc-output value
 
DC Output Voltage : 53.997 V
 
DC Output Current : 0.000 A 
display poe-power 
switch state
Syntax
display poe-power switch state
View
Any view
Parameter
None
Description
Use the display poe-power switch state command to display the number and 
current state of the AC power distribution switches of the PSUs.
Example
# Display the number and current state of the AC power distribution switches.
<SW8800>display poe-power switch state
 
 Switch Number : 0 
display 
supervision-module 
information
Syntax
display supervision-module information
Table 122   Description on the fields of the display poe-power switch state command
Field 
Description 
On 
The switch is on. 
Off 
The switch is off. 
High Volt Input  The input is high voltage. 
Low Volt Input  The input is low voltage.