3com 8807 Reference Guide

Page of 1099
988
C
HAPTER
 58: D
EVICE
 M
ANAGEMENT
 C
OMMANDS
Parameter
hhh:mm: Waiting time for rebooting a switch, in the format of "hour: minute" 
The hhh ranges from 0 to 720, and the mm ranges from 0 to 59.
mmm: Waiting delay for rebooting a switch, in the format of "absolute minutes" . 
Ranging from 0 to 43200,
Description
Use the schedule reboot delay command to enable the timing reboot switch 
function and set the waiting time.
Use the undo schedule reboot command to disable the timing reboot function.
By default, the timing reboot switch function is disabled.
The precision of switch timer is 1 minute. The switch will reboot in one minute 
when time comes to the specified rebooting point.
Two formats can be used to set the waiting delay of timing reboot switch, namely 
the format of "hour: minute" and the format of "absolute minutes". But the total 
minutes should be no more than 30Ðó24Ðó60 minutes, or 30 days.
After this command is configured, the system will prompt you to input 
confirmation information. Only after the "Y" or the "y" is entered can the 
configuration be valid. If there is related configuration before, it will be covered 
directly.
Moreover, after the schedule reboot at command is configured, and the system 
time is adjusted by the clock command, the original schedule reboot at 
parameter will become invalid.
Related command: rebootschedule reboot atundo schedule reboot
display schedule reboot.
Example
# Configure the switch to be restarted after 88 minutes (the current time is 21:32).
<SW8800> schedule reboot delay 88
 
Reboot system for 23:00:00 UTC 2002/11/1 (in 1 hours and 28 minutes)
 
Confirm? [Y/N]:y 
temperature-limit
Syntax
temperature-limit slot-no down-value up-value
undo temperature-limit slot-no
View
User view
Parameter
Slot-no: Physical card number.
down-value: Lower temperature limit, in the range 0 to 70 °C.