3com 8807 Reference Guide

Page of 1099
1084
C
HAPTER
 66: NQA C
ONFIGURATION
 C
OMMANDS
Parameter
times: Number of constant test failures.
Description
Use the test-failtimes command to set the number of constant test failures after 
which the system will send the Trap information to the network management 
system.
Use the undo test-failtimes command to restore the number of constant test 
failures to the default value.
By default, the system sends the Trap information to the network management 
system after one NQA test fails.
For the concept of test and probe, note the following content:
When probing, the system sends one packet every time. While the test process 
is not always so.
One test may include many probes. The test succeeds as long as there is one 
successful probe.
The current "probe failure times" will be reset to zero after a test is finished, 
that is, the "times" is only valid for a single test and can not cross two tests for 
constant statistics. If the probe succeeds, this statistic value is reset to zero too.
Related command: probe-failtimes.
Example
# Set that the system sends Trap information after 3 constant probe failures in an 
NQA test.
<SW8800>system-view
 
System View: return to User View with Ctrl+Z.
 
[SW8800] nqa-agent enable
 
[SW8800] nqa administrator icmp
 
[3Com-administrator-icmp] test-failtimes 3 
test-type
Syntax
test-type type
View
NQA test group view
Parameter
type: Type of test, currently it is only the icmp type.
By default, the test type is icmp.
Description
Use the test-type command to configure the test type.
The test type is required, so no undo command is provided.