3com 8807 Reference Guide
PoE PSU Supervision Display Commands
891
display poe-power
dc-output value
Syntax
display poe-power dc-output value
View
Any view
Parameter
None
Description
Use the display poe-power dc-output value command to display the DC
output voltage/current value of the PoE PSUs.
output voltage/current value of the PoE PSUs.
Example
# Display the DC output voltage/current value of the PoE PSUs.
<SW8800> display poe-power dc-output value
DC Output Voltage : 53.997 V
DC Output Current : 0.000 A
display poe-power
switch state
Syntax
display poe-power switch state
View
Any view
Parameter
None
Description
Use the display poe-power switch state command to display the number and
current state of the AC power distribution switches of the PSUs.
current state of the AC power distribution switches of the PSUs.
Example
# Display the number and current state of the AC power distribution switches.
<SW8800>display poe-power switch state
Switch Number : 0
display
supervision-module
information
Syntax
display supervision-module information
Table 122 Description on the fields of the display poe-power switch state command
Field
Description
On
The switch is on.
Off
The switch is off.
High Volt Input The input is high voltage.
Low Volt Input The input is low voltage.