3com 8807 User Guide

Page of 883
Ethernet Port Troubleshooting
99
[SW8800] interface gigabitethernet2/1/1 
# Set the GigabitEthernet2/1/1 as a trunk port and allows VLANs 2, 6 through 50, 
and 100 to pass.
[3Com-GigabitEthernet2/1/1] port link-type trunk
 
[3Com-GigabitEthernet2/1/1] port trunk permit vlan 2 6 to 50 100 
# Create the VLAN 100.
[SW8800] vlan 100 
# Configure the default VLAN ID of GigabitEthernet2/1/1 as 100.
[3Com-GigabitEthernet2/1/1] port trunk pvid vlan 100 
Ethernet Port 
Troubleshooting
Symptom 1: Default VLAN ID configuration fails.
Solution: Take the following steps:
Execute the display interface or display port command to check if the port 
is a trunk port or a hybrid port. If it is neither of them, configure it as a trunk or 
hybrid port.
Then configure the default VLAN ID.
Symptom 2: The port is in down status.
Solution: Please check
If the cable connection is correct and if the optical fiver cable is inversely 
connected.
If the shutdown command is used on the port.
If the right optical module is inserted.