Alternatively, the Switch can be rack-mounted in a 
wiring closet or equipment room. A mounting kit, 
containing two mounting brackets and four screws, is 
supplied with the Switch.
When deciding where to position the Switch, ensure 
that:
It is accessible and cables can be connected easily.
Cabling is away from sources of electrical noise. 
These include lift shafts, microwave ovens, and air 
conditioning units. Electromagnetic fields can 
interfere with the signals on copper cabling and 
introduce errors, therefore slowing down your 
network.
Water or moisture cannot enter the case of the unit.
Air flow around the unit and through the vents in 
the side of the case is not restricted (3Com 
recommends that you provide a minimum of 25 mm 
(1 in.) clearance).
The air is as free of dust as possible.
Temperature operating limits are not likely to be 
exceeded. It is recommended that the unit is 
installed in a clean, air conditioned environment.
It is always good practice to wear an anti-static wrist 
strap when installing network equipment, connected to 
a ground point. If one is not available, try to keep in 
contact with a grounded rack and avoid touching the 
unit's ports and connectors, if possible. Static discharge 
can cause reliability problems in your equipment.
Rack-Mounting or Free-Standing
The unit can be mounted in a 19-inch equipment rack 
using the mounting kit or it can be free-standing. Do 
not place objects on top of the unit or stack. 
CAUTION: If installing the Switch in a free-standing 
stack of different size Baseline or Superstack
®
 3 units, 
the smaller units must be installed above the larger 
ones. Do not have a free-standing stack of more than 
six units.
Using the Mounting Kit
The Switch is supplied with two mounting brackets and 
four screws. These are used for rack mounting the unit. 
When mounting the unit, you should take note of the 
guidelines given in “Positioning the Switch” on 
page 13
The Switch is 1U high and will fit in a standard 19-inch 
rack.
CAUTION: Before continuing, disconnect all cables from 
the unit. Remove the self-adhesive pads from the 
underside of unit, if already fitted.
To rack-mount the Switch:
1
Place the unit the right way up on a hard, flat surface 
with the front facing towards you.
2
Locate a mounting bracket over the mounting holes on 
one side of the unit.