3com 2500 Quick Setup Guide

Page of 110
4-4
C
HAPTER
 4: C
ABLING
Cabling the 10BASE-T (RJ-21) Module
The 10BASE-T (RJ-21) module provides eight 
10BASE-T connections with one Telco connector. 
The connections are implemented as MDI-X (media 
dependent interface crossover) connections, 
meaning that a workstation or other DTE can be 
directly connected to the port with a 
straight-through cable. 
To cable the 10BASE-T (RJ-21) module:
1
Insert the mounting post and washer into the 
threaded hole of the cable end of the male Telco 
connector.
2
Connect the male Telco connector on the 10BASE-T 
cable to the female Telco connector on the module. 
Ensure that the slide latch is to the right.
3
Slide the latch to the left and ensure it grips the 
mounting posts.
4
Tighten the connector securing screws.
5
Attach the other end of the 10BASE-T cable in one 
of these ways:
Attach it to a harmonica panel with RJ-45 ports, 
as described in the next section. 
Punch the individual wires into a Type 66 or Type 
110 punch-down block, as described on page 4-5 
in 
(RJ-21) module using 10BASE-T cable.
Figure 4-2   Cabling the 10BASE-T (RJ-21) Module
Connecting 10BASE-T (RJ-21) to a Harmonica 
Panel
Up to three modules with RJ-21 connectors can 
connect to a single harmonica panel, each through 
a 50-pin connector. Each harmonica panel provides 
24 RJ-45 connections for various network devices. 
 shows the back 
of the panel, including the connections for the 
50-pin connectors. Harmonica panels are available 
from 3Com. 
Port Status
Active
Error
1
2
3
4
5
6
7
8
Inserted
PCMCIA
ard
or
Port Status
Active
Error
RJ-21 connector
10BASE-T (RJ-21)
module
10BASE-T cable
Securing screws