3com 7000 Supplementary Manual

Page of 516
208
C
HAPTER
 7: C
ONFIGURING
 V
IRTUAL
 C
HANNELS
Update
CALL-PROCEEDING
Suppression
Updates the signaling call-proceeding suppression facility and saves it in 
flash memory. For more details, “Display CALL-PROCEEDING Suppression 
Status” on page 207
.
This command also causes the call-proceeding flag to be saved in flash 
memory.
Command Actions
Command Result
Example
Enter: 
1 1 4 6 2 1 
The following message is displayed:
The call-proceeding flag was successfully set to on.
The call-proceeding enable flag is updated to ON and the new value is 
saved in flash memory.
Enter the menu sequence: 
(1) SYS: Platform config
 (1) SET: Switch setup
  (4) SIG: Signaling setup
   (6) CCL: Signaling call ctrl setup
    (2) SET: Set & save call proc flag
Enter a parameter at the prompt
Parameter
Format or Range
Call-proceeding message 
enable/disable flag
0
 to suppress call-proceeding messages 
1
 to send call-proceeding messages
Direct access sequence:
1 1 4 6 2 
[parameters]
System action taken:
The call-proceeding enable flag is updated. The new 
value is saved in flash memory.
System message display:
The call-proceeding flag was 
successfully set to on/off.