# Set the maximum number of commands the history command buffer can store to 20. 
[Sysname-ui-aux0] history-command max-size 20 
# Set the timeout time of the AUX user interface to 6 minutes. 
[Sysname-ui-aux0] idle-timeout 6 
After the above configuration, to ensure a successful login, the console user needs to change the 
corresponding configuration of the terminal emulation program running on the PC, to make the 
configuration consistent with that on the switch. Refer to 
 
for details. 
Console Port Login Configuration with Authentication Mode Being 
Scheme 
Configuration Procedure 
Follow these steps to perform Console port login configuration (with authentication mode being 
scheme): 
To do… 
Use the command… 
Remarks 
Enter system view 
system-view 
— 
Enter AUX user interface 
view 
user-interface aux first-number 
last-number ] 
— 
Configure to authenticate 
users locally or remotely 
authentication-mode scheme 
Required 
The specified AAA scheme 
determines whether to 
authenticate users locally or 
remotely. 
By default, users logging in 
through the Console port are not 
authenticated 
Quit to system view 
quit 
—