3com S7906E Installation Instruction
1-4
z
A statistics object of the history group is the variable defined in the history record table, and the
recorded content is a cumulative sum of the variable in each period. For detailed configuration,
Configuring the RMON Ethernet Statistics Function
Follow these steps to configure the RMON Ethernet statistics function:
To do…
Use the command…
Remarks
Enter system view
system-view
—
Enter Ethernet interface view
interface interface-type interface-number
—
Create an entry in the RMON
statistics table
statistics table
rmon statistics entry-number [ owner
text ]
text ]
Required
z
Only one statistics entry can be created on one interface.
z
You can create up to 100 statistics entries for the device.
Configuring the RMON History Statistics Function
Follow these steps to configure the RMON history statistics function:
To do…
Use the command…
Remarks
Enter system view
system-view
—
Enter Ethernet interface view
interface interface-type interface-number
—
Create an entry in the RMON
history control table
history control table
rmon history entry-number buckets
number interval sampling-interval [ owner
text ]
number interval sampling-interval [ owner
text ]
Required
z
The entry-number must be globally unique and cannot be used on another interface; otherwise, the
operation fails.
z
You can configure multiple history entries on one interface, but the values of the entry-number
arguments must be different, and the values of the sampling-interval arguments must be different
too; otherwise, the operation fails.
z
You can create up to 100 history entries for the device.
z
When you create an entry in the history table, if the specified buckets number argument exceeds
the history table size supported by the device, the entry will be created. However, the validated
value of the buckets number argument corresponding to the entry is the history table size