3com 3C17204 User Guide

Page of 100
24
C
HAPTER
 2: I
NSTALLING
 
THE
 S
WITCH
Package Contents
Switch unit
CD-ROM (includes documentation related to your Switch)
Getting Started Guide (this guide)
Management Quick Reference Guide
Release Notes
Unit Information Labels
Warranty Information
Power Cord 
2 x Mounting brackets
4 x Screws
4 x Rubber feet
Choosing a Suitable 
Site
The Switch is suited for use on a desktop, either free standing or 
mounted in a standard 19-inch equipment rack. Alternatively, the Switch 
can be mounted in a wiring closet or equipment room, as an aggregator 
for other Hubs and Switches. A rack-mounting kit containing two 
mounting brackets is supplied with the Switch.
CAUTION: Ensure that the ventilation holes are not obstructed.
When deciding where to position the Switch, ensure that:
Cabling is located away from:
sources of electrical noise such as radios, transmitters and 
broadband amplifiers. 
power lines and fluorescent lighting fixtures
The Switch is accessible and cables can be connected easily.
Water or moisture cannot enter the case of the Switch.
Air flow is not restricted around the Switch or through the vents in the 
side of the Switch. 3Com recommends that you provide a minimum of 
25mm (1in.) clearance.
Air temperature around the Switch does not exceed 40 
°C
 (104 
°
F).
If the Switch is installed in a 19-inch rack or closed assembly its local air 
temperature may be greater than room ambient temperature.