4 Power  LED
The Power LED indicate the status of the unit's internal 
power as follows:
Rear Panel Connections
5 Power Supply
The Baseline 10/100/1000 Switch 6-Port automatically 
adjusts to the supply voltage. Only use the power cord 
that is supplied with the unit.
6 Socket for Redundant Power System (RPS)
Connect a 3Com SuperStack 3 Advanced RPS (3C16070, 
3C16071, 3C16071A, or 3C16071B) only to this socket. 
An appropriate power module and cable is required. The 
connector on the Baseline 10/100/1000 Switch 6-Port 
requires a Type 2A module. For details, follow the 
installation instructions in the guides that accompany the 
Advanced RPS and the power module.
Positioning the Switch
When deciding where to position the Baseline 
10/100/1000 Switch 6-Port ensure:
„
It is accessible and cables can be connected easily.
„
Cabling is away from sources of electrical noise. 
These include lift shafts, microwave ovens, and air 
conditioning units. Electromagnetic fields can inter-
fere with the signals on copper cabling and intro-
duce errors, therefore slowing down your network.
„
Water or moisture cannot enter the case of the unit.
„
Air flow around the unit and through the vents in the 
side of the case is not restricted (3Com recommend 
that you provide a minimum of 25 mm (1 in.) clear-
ance).
„
The air is as free from dust as possible.
„
Temperature operating limits are not likely to be 
exceeded. It is recommended that the unit is installed 
in a clean, air conditioned environment.
It is always good practice to wear an anti-static wrist 
strap when installing network equipment, connected to 
a ground point. If one is not available, try to keep in 
contact with a grounded rack and avoid touching the 
unit's ports and connectors, if possible. Static discharge 
can cause reliability problems in your equipment.
Rack Mounting or Free Standing
This unit can be mounted in a 19-inch equipment rack 
using the Mounting Kit. Refer to 
 on 
. It can also be free standing. Do 
not place objects on top of the unit or stack. 
The unit is supplied with four self-adhesive rubber pads. 
If the unit is to be part of a free standing stack, apply 
the pads to each marked corner area on the underside 
of the unit. Place the unit on top of the lower unit, 
ensuring that the pads locate with the recesses of the 
lower unit.
You do not need to apply the pads if you intend to rack 
mount the unit.
CAUTION: If installing the Baseline 10/100/1000 Switch 
6-Port in a free standing stack of different size 
SuperStack II or SuperStack 3 units, the smaller units 
must be installed above the larger ones. Do not build a 
free standing stack of more than six units.
Connecting to a Network Device
Follow these guidelines to connect a device to the 
Baseline 10/100/1000 Switch 6-Port:
„
Use Category 5 unshielded or shielded (screened) 100 
Ohm TP cable (or Category 3 cable for a 10 Mbps 
connection). 
„
The maximum length of cable for each connection is 
100m (328ft). 
„
Connect one end of the cable to an RJ-45 port on 
the Baseline 10/100/1000 Switch 6-Port, and the 
other end to the appropriate RJ-45 port on the con-
necting device.
Power Supply
Power problems can be the cause of serious failures and 
downtime in your network. Ensure that the power input 
to your system is clean and free from sags and surges to 
avoid unforeseen network outages. 3Com recommends 
that you install power conditioning, especially in areas 
prone to black outs, power dips and electrical storms.
The unit is intended to be grounded. Ensure it is 
connected to earth ground during normal use. Installing 
proper grounding helps to avoid damage from lightning 
and power surges.
Powering Up
Use the following sequence to power up the Baseline 
10/100/1000 Switch 6-Port:
Check the network connections and cables.
Connect the power supply cable to the appropriate 
power socket on the rear panel of the unit; see refer-
ence 5 or in “Features of the Baseline 10/100/1000 
Switch”.
Connect the plug to the power supply outlet socket and 
switch on the power supply at the socket. If you are 
using the Advanced Redundant Power System, ensure it 
is powered on.
When the switch is powered on, the Power LED lights 
green. If it does not, see reference 4 in “Features of the 
Baseline 10/100/1000 Switch”.
Status
Meaning
Off
Unit power rails faulty
Green
Normal operation; all power rails functional
Yellow
Unit shutdown due to excessive temperature. Refer to “Prob-
lem Solving on 
I
NSTALLING
 
THE
 S
WITCH
!
3