3com 3c16465b User Guide

Page of 8
3
Display Function Switch
This switch affects the Status LEDs described in 4 and 5.
4
Activity/Duplex Status LEDs
The first (top) and third row of LEDs, which are colored yellow, 
show the activity or duplex status of the related ports:
„
When the Display Function switch is out (its normal position), 
these LEDs show the activity of each port. The LED flashes 
when packets are received or transmitted on the port.
„
When the Display Function switch is pressed in, these LEDs 
show the duplex status of each port:
5
Link/Speed Status LEDs
The second and fourth (bottom) row of Status LEDs, which are 
colored green, show the link or speed status of the related ports:
„
When the Display Function switch is out (its normal position), 
these LEDs show the link status of each port:
„
When the Display Function switch is pressed in, these LEDs 
show the speed status of each port:
6
Power/Self Test LED
The Power/Self test LED shows a number of conditions:
Rear Panel Connections
7
Power Supply
The Baseline 10/100 Switch automatically adjusts to the supply 
voltage. Only use the power cord that is supplied with the 
Baseline 10/100 Switch.
8
Socket for Redundant Power System (RPS)
Only connect a 3Com SuperStack 3 Advanced RPS (3C16070, 
3C16071, 3C16071A or 3C16071B) to this socket. An 
appropriate power module and cable is required. The connector 
on the Baseline 10/100 Switch is a Type 2 socket. For details, 
follow the installation instructions in the guides that accompany 
the Advanced RPS and the power module.
CAUTION: When connecting an RPS power module cable 
to the unit, take off the protective cover by removing the 
fixings with a suitable tool. Keep the cover and the fix-
ings in a safe place. If you remove the RPS power module 
cable at any time, you must replace the protective cover.
9
Self-adhesive Pads
The unit is supplied with four self-adhesive rubber pads.
You do not need to apply the pads if you intend to rack 
mount the unit.
If the unit is to be part of a free standing stack, apply the pads to 
each marked corner area on the underside of the unit. Place the unit 
on top of the lower unit, ensuring that the pads locate with the 
recesses of the lower unit.
Positioning the Baseline 10/100 Switch
CAUTION: If installing the Baseline 10/100 Switch in a 
stack of different size SuperStack 3 units, the smaller 
units must be installed above the larger ones. Do not 
have a free standing stack of more than six units.
When deciding where to position the Baseline 10/100 Switch  
ensure:
„
It is accessible and cables can be connected easily.
„
Cabling is away from sources of electrical noise such as 
radios, transmitters and broadband amplifiers, and away from 
power lines and fluorescent lighting fixtures.
„
Water or moisture cannot enter the case of the unit.
„
Air flow around the unit and through the vents in the side of 
the case is not restricted (3Com recommend that you provide 
a minimum of 25mm (1in.) clearance).
To prolong the operational life of your units:
„
Never stack units more than six high if free standing, and 
ensure that cables are supported so that they do not cause 
the stack to fall over.
„
Do not place objects on top of any unit or stack.
„
Do not obstruct any vents at the sides of the case.
Rack Mounting
The Baseline 10/100 Switch can be mounted in a 19-inch equip-
ment rack using the Mounting Kit. Refer to “Mounting Kit 
Instructions”
 on page 5. 
Power Up
Use the following sequence to power up the Baseline 10/100 
Switch :
„
Check the network connections and cables.
„
Connect the power supply cable to the appropriate power 
socket on the rear panel of the unit; refer to 7 or 8.
„
Connect the plug to the power supply outlet socket and 
switch on the power supply at the socket. If you are using 
the Advanced Redundant Power System, ensure it is pow-
ered on.
When the switch is powered on, the Power/Self Test LED should 
first flash green, then stay lit. If it does not, refer to 6.
Spot Checks
At frequent intervals you should visually check the Baseline 
10/100 Switch. Regular checks can give you an early warning of a 
possible failure; any problems can then be attended to when 
there will be least effect on users. Check the following:
If you experience any problems operating the Baseline 10/100 Switch, 
refer to “Problem Solving” on page 5.
Out
This is the normal position of the switch. 
The Status LEDs show the Activity and Link Status of 
each port.
In
When the switch is pressed in, the Status LEDs show 
the Duplex and Speed Status of each port. The switch 
returns to the out position when released. 
On
The port is operating in full duplex mode.
Off
Ports 1 to 24: If the link is established, the port is operating in 
half duplex mode. 
On
The link has been established and the segment attached to the 
port is functional.
Off
The link has not been established. Either nothing is connected 
to the port, or there is a problem:
Check that the attached device is powered on.
Check that the cable is the correct type and is not faulty.
If the LED is off for port 12 (3C16464B) or 24 (3C16465B), 
check the setting of the MDI switch. Refer to 2. Try toggling the 
MDI switch.
If the port is connected to another unit’s MDI/MDIX port, check 
the other unit’s MDI switch position.
If these checks do not identify the cause of a problem, it may 
be that the unit or the device connected to the port is faulty. 
Contact your supplier for further advice.
On
The link is operating at 100Mbps.
Off
If the link is present, it is operating at 10Mbps.
Green
The unit is powered on and ready for use.
Flashing
green
The unit is performing its power up procedure. If the LED is still 
flashing green 1 minute after power up, there is a fault. Con-
tact your supplier.
Yellow
The unit has failed. Power off the unit, wait five seconds and 
power on the unit. Contact your supplier if the LED continues 
to light yellow.
Off
The unit is not receiving power:
Check the power cord is connected correctly.
If the unit still does not operate, contact your supplier.
Cabling
Check that all external cabling connections are secure 
and that no cables are pulled taut.
Cooling fans
Where possible, check that the cooling fans are operat-
ing by listening to the unit. The fans are fitted near to 
the front right hand side of the unit (when viewed from 
the front).
!
3