Xerox 4050 Installation Instruction

Page of 64
PREINSTALLATION
Environmental and electrical requirements
This section provides important environmental and electrical
requirements for your LPS that must be accommodated. 
4050
Environmental and electrical requirements for the 4050 LPS are
provided in table 1-15 and 1-16. 
Table 1-15.
Environmental requirements
Operating temperature
Normal: 68° F to 76° F/20° C to 24° C 
Minimum: 60° F/16° C 
Maximum: 80° F/27° C
Humidity 
Normal: 45 +/- 10% 
Minimum: 30% 
Maximum: 60% 
Heat dissipation, online
Operating:
15,000 BTU per hour  
Standby:
7,500 BTU per hour 
Heat dissipation, offline
Operating:
15,500 BTU per hour  
Standby:
8,000 BTU per hour 
Table 1-16.
Electrical requirements
System controller
120/208 or 120/240 VAC; 50/60 Hz, 
30 amp service, NEMA L14-30R
1.5 KVA both in standby mode and when
operating 
Note:  Magnetic tape unit assumed
(maximum draw) 
Printer 
U.S./Canada, 60 Hz: 120/208 or 120/240
VAC; 30 amp service, NEMA 14-30R 
.875 KVA in standby, 3.1 when operating 
International, 50 Hz: 
220/240 VAC or 380 VAC 
Agency certification
UL, CSA, IEC
1-18