Xerox 8830 folder Service Manual

Page of 51
September 2001
88XX Series Folder Operator Manual   16
Switching on the Folder
At power on, the Firmware release will be displayed for two seconds:
−  as a code in the Numeric Control Panel [RX.XX ]
−  as 
a
 message in the Alphanumeric Control Panel “REV. X.XX“
When 2 - 3 seconds has expired, the control panels will show either
“idle”, an alarm status or (if the system has already submitted a job), the
program selected.
−  as a code in the Numeric Control Panel [ le], [A-XX] or [P-XX].
−  as a message in the Alphanumeric Control Panel “IDLE”,
“190+20” or “DOOR OPEN”
During the folding process, error messages will be displayed:
−  as a code in the Numeric Control Panel [E-XX]
−  as a message in the Alphanumeric Control Panel
Code
Message
Code
Message
a-
01
DOOR OPEN
a-07
ENCODER OR M2 MOTOR FAULT
a-
02
BRIDGE SENSORS
COVERED
a-08
STEP MOTORS FAULT
a-
03
UPPER POCKET
SENSOR COVERED
a-09
NOT IMPLEMENTED
a-
04
LOWER POCKET
SENSOR COVERED
a-10
NOT IMPLEMENTED
a-
05
CROSS POCKETS
SENSOR COVERED
a-11
FIRST BIN FULL
a-
06
24V MISSING
a-12
SECOND BIN FULL
Other errors
Code
Description
S
Not settable value. Folder could generate unexpected
folding styles due to particular value situation.
Is not possible to adjust the style
Code
Message
Code
Message
p-00
NO FOLD
P-10
CUSTOM
p-01
185
p-11
7,5”
p-02
185+25
p-12
7,5”+1”
p-03
190
P-13
8,5”
p-04
190+20
P-14
9”
p-05
198
p-15
WALLET 11”
p-06
210
p-16
WALLET 12”
p-07
AFNOR
p-17
7,5” LANDSCAPE
p-08
ERICSSON
p-18
8,5” LANDSCAPE
p-09
FRENCH
p-19
9” LANDSCAPE
Code
Message
e-01
ENTRY ALARM 1
e-02
ENTRY ALARM 2
e-03
BRIDGE ALARM
e-04
ROTATION ALARM
e.-05
POCKETS ALARM
e-06
FOLDING ALARM 1
e-07
FOLDING ALARM 2
e-08
FOLDING ALARM 3
e-09
FAN FOLDER EXIT ALARM
e-10
TRANSPORT ALARM
e-11
CROSS ENTRY ALARM
e-12
CROSS EXIT ALARM
CROSS EXIT ALARM W/PUNCHING
e-13
NOT FOLDABLE
E-14
NOT AVAILABLE SELECTION
E-15
LAPS WITHOUT ADJUSTMENT
E-16
E-17
PROGRAM NOT SELECTABLE
Note : 
SENSOR COVERED ¡ SENSOR UNCOVERED