Xerox 4508 User Guide

Page of 150
O p t i o n s   I n s t a l l a t i o n
B-2  ❖   D o c u P r i n t   4 5 0 8   U s e r   G u i d e
RS232C Serial
Interface
Option
Installation
Serial Interface
Specifications
The RS232C serial option module lets you communicate with 
the computer up to a maximum speed of 115,200 bps (bits per 
second). 
The data format used in serial transmission is fixed at 8 data 
bits, 1 stop bit and no parity. 
The flow control can be either of the following: 
DTR signal (hardware handshake)   
XON/XOFF (software handshake). 
Apart from the XON/XOFF flow control, you can select 
whether you will be using robust XON protocol which lets the 
printer keep sending the XON signal repeatedly within a 
preset interval (e.g. every one second).
The transmission speed and robust XON can be selected in 
the Remote Control Panel. 
4508-apb.frm  Page 2  Wednesday, May 22, 1996  8:30 AM