Please ensure electrical, space, and supplies are available prior to equipment delivery.
 
Customer Support 
The Xerox Customer Support Center is available to provide general 
information, answer questions, and take service calls. You can reach 
the Customer Support Center at the following toll-free phone number: 
United States 
1-800-821-2797 
Your Xerox Analyst will provide fee-based training upon request. 
 
Space Requirements / Service Envelope
 
The components of the DocuTech 6180 system are: 
•  DocuSP Controller (monitor, keyboard, mouse) 
•  Printer 
WIDTH
DocuTech 61xx
Representation only.
D
E
P
T
H
 
 
Note: The 6155 and 6180 are available with and without a stand to 
support the controller.  If a stand (098S04797) is ordered, it will be 
positioned to the left of the printer, within the service space envelope. 
If no stand is ordered, the controller will be placed on the floor to the 
left of the printer in the service space envelope.  
Note:  The dimensions shown below provide the overall service 
space required, including the space to the nearest obstruction.  The 
dimensions are in 
inches
 and are absolute minimums 
 
 
With stand
Without stand
Configuration 
Width Depth Width Depth 
6155, 6180 with 
interposer and 
finisher 
243.0" 114.0”  240.0” 114.0" 
 
Electrical Requirements – DocuTech 6155 / 6180 
For the printer one (1) electrical service option is available – 2-phase, 
dual power cord. 
 
 
MultiSource 
2-phase, dual power cord 
configuration 
Voltage 208/240
(4 wire)
 208/240 
(4 wire)
 
Amperage 50 
30 
Cycles 
60 Hz 
60 Hz 
Receptacle Xerox Part No. 
600S3779 
600S3277 
Receptacle NEMA Part No. 
14-50R 
14-30R 
Receptacle Diagram 
 
 
Power Cord Kit Number 
98K59581 
 
Power Cord Length 
15 feet 
15 feet 
 
Electrical Requirements 
Digital Front End (DFE) Controller Platform:
 
Line Options: 
Dedicated 
Voltage 110 
Amperage 15 
Cycles 60 
Hz 
15 amp Receptacle Xerox Part No. 
20 amp Receptacle Xerox Part No. 
600S3704 
600S3703 
Receptacle NEMA Part No. 
5 - 20R or 5 - 15R 
Receptacle Diagram 
 or 
 
 
• 
All controller configurations require a 110VAC, 15 Amp 
grounded receptacle for the outlet strip that provides
 receptacles 
for the 
controller and its peripheral devices (monitor, modem, 
CDROM drive, and tape drive) 
• 
Adapters that eliminate the ground connection to the outlet can 
not be used
• 
Xerox provides 15 feet of cabling with Teflon coating (Plenum 
rated), to connect the controller to the Processor/Finisher. 
 
Environmental Requirements  
 
 
Recommended Min. 
Max. 
Temperature  
68
o
 F – 76
o
(20
o
 C-24
o
 C)
 
50 
o
 F     
(10
o
 C)
 
85
o
 F* 
(29
o
 C)
 
Humidity 
45% +/-10% 
30% RH 
60%  RH 
Heat Emission – 
with Binder On 
(with processor, 
interposer, finisher 
and binder) 
- 14,185 
BTU/Hr  
(with vent kit)
 
22,165 
BTU/Hr 
(Running) 
Heat Emission – 
with Binder Off 
(with processor, 
interposer, finisher 
and binder) 
- 13,609 
BTU/Hr  
(with vent kit)
 
21,265 
BTU/Hr 
(Running) 
Altitude (above 
sea level) 
Up to 6,000 ft. 
9,000 ft. 
* The system will inhibit software problems and shut down above 90 
o
 F