Xerox 75 User Guide

Page of 68
Installation Planning Guide
Planning for the installation
DocuTech/DocuPrint 75/90 and DocuPrint 75 MX 
3-3
WARNING
Do not remove or modify the power cord plug. Do not use a 
two-prong adapter to connect the three-prong plug to an 
ungrounded receptacle. Personal injury or damage to the 
printer could occur. 
A typical USA 20 Amperes receptacle is illustrated in 
Figure 3-1. USA 20 Amp receptacle
The power receptacle for the printer must be within easy 
reach of the printer’s 10 ft. (3 m) power cord from the right 
rear corner of the printer and the receptacle shall be easily 
accessible. Do not use an extension cord.
If a Phone Share device is used an additional 115V AC 15 or 
20 Amp power receptacle is required within 6 ft. (1.8 m) of the 
PhoneShare device location. For detailed information about 
using a Phone Share device, refer to the section, Telephone 
line requirements. 
All configurations require one 115 VAC, 3 wire, 15 Amp 
receptacle for the outlet strip that provides receptacles for the 
controller and its peripheral devices.
Use the power strip to connect the telephone line with the 
controller external modem. The power strip has two special 
surge-suppressor jacks, one labeled “In” and the other 
labeled “Out.” From the wall jack, insert the phone line into 
the power strip “In” jack. From the power strip “Out” jack, 
insert the phone line into the controller external modem. 
Telephone line requirements
NOTE:   The telephone line for the Sixth Sense feature must be 
an analog telephone line (not a digital telephone line).
The Sixth Sense connection requires either a dedicated 
analog telephone line or a PhoneShare device to share an 
analog telephone line with up to three other devices.