A-6
Phaser 300X Color Printer
Serial port
The printer’s serial port provides an RS-232 interface connection to PCs and 
other hosts.  The printer’s serial port has these built-in default settings.  
Variable (factory default, Switch 7down)
Baud rate — 9600
Flagging — Software (XON/XOFF)
Parity — None
Stop bits — 1
Data bits — 8
Check parity — False
Protocol — Normal
When Switch 7 on the printer’s rear panel is in the down position, 
you can change the default setting.  To change the serial port’s 
settings, you can use the PostScript Level 2 setdevparams 
command.  Refer to the Phaser 300X Drivers and Utilities Printing 
Reference
 for details.
Fixed (Switch 7up)
Baud rate — 1200
Flagging — Software (XON/XOFF)
Parity — Space
Stop bits — 1
Data bits — 7
Check parity — False
Protocol — Normal