Xerox 750P User Guide

Page of 118
Advanced Features and Troubleshooting Manual
103
Environmental Specifications (Temperature/Humidity/Power)
Environmental Specifications 
(Temperature/Humidity/Power)
Operating range: temperature and humidity
The operating range is contained within the temperature/humidity space defined by the 
following points: 
Celsius:
15 degrees Celsius, 10 percent relative humidity
32 degrees Celsius / 10 percent relative humidity
32 degrees Celsius / 60 percent relative humidity
25.5
 
degrees Celsius / 80 percent relative humidity
15 degrees Celsius / 80 percent relative humidity
Fahrenheit:
60 degrees Fahrenheit, 10 percent relative humidity
90 degrees Fahrenheit / 10 percent relative humidity
90 degrees Fahrenheit / 60 percent relative humidity
78 degrees Fahrenheit / 80 percent relative humidity
60 degrees Fahrenheit / 80 percent relative humidity
The best print quality is obtained within these limits:
18 degrees to 25.5 degrees C
elsius
 (64 degrees to 78 degrees F
ahrenheit
), and 30 percent to 
80 percent relative humidity
Temperature
Non-operating: 0 degrees C
elsius
 to 40 degrees C
elsius
 (32 degrees F
ahrenheit
 to
104 degrees F
ahrenheit
)
Storage: (without paper, transparencies, or consumables): –20 degrees C
elsius
 to 
+60 degrees C
elsius
 
(–4 degrees F
ahrenheit
 to +140 degrees F
ahrenheit
)
Humidity
Non-operating: 10 percent to 90 percent relative humidity, non-condensing
Altitude
Operating: 0 to 2,500 m (8,000 ft.). 
Non-operating: 0 to 4000 m (13,125 ft.)
Primary voltage ranges
90 - 132 VAC, 110 VAC nominal
198 - 264 VAC, 220 VAC nominal
Frequency range
50 to 60 Hz
Primary fusing
125 VAC, 10 Amps and 8 Amps
250 VAC, 5 Amps and 4 Amps
(Not user-accessible)